16
S4TEF10xx-10x
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Troubleshooting -- Continued
5. Is data transfer failing on one of the T1/E1 ports?
YES
• Verify the local T1/E1 connection at the local converter by starting a
local loop-back at the local converter:
- HW mode: set the local converter to T1/E1 loop-back (see page 4).
- SW mode: enter the local T1/E1 loop-back command at the local
converter.
• Use a bit error test unit to run a bit error test.
• Verify the remote T1/E1 connection at the local converter by starting a
remote loop-back at the local converter:
- SW mode: enter the remote T1/E1 loop-back command at the local
converter. (HW mode is not available.)
• Use a bit error test unit to run a bit error test.
• Verify the remote T1/E1 connection at the remote converter by starting a
remote loop-back at the remote converter:
- SW mode: enter the remote T1/E1 loop-back command at the remote
converter. (HW mode is not available.)
• Use a bit error test unit to run a bit error test.
• Verify the local T1/E1 connection at the remote converter by starting a
local loop-back at the remote converter:
- HW mode: set the remote converter to T1/E1 loop-back (see page 4).
- SW mode: enter the local T1/E1 loop-back command at the remote
converter.
• Use a bit error test unit to run a bit error test.
FiberT1 T1
Local
Converter
Remote
Converter
Bit Error Test
Equipment
Remote
Device
FiberT1 T1
Local
Converter
Remote
Converter
Bit Error Tes
Equipment
Remote
Device
FiberT1 T1
Local
Converter
Remote
Converter
Remote
Device
Bit Error Tes
Equipment
FiberT1 T1
Local
Converter
Remote
Converter
Remote
Device
Bit Error Test
Equipment
17
Troubleshooting -- Continued
6. Is data transfer failing on the fiber port?
YES
• Verify the local fiber connection by starting a remote fiber loop-back:
- HW mode: set the remote converter to fiber loop-back (see page 7).
- SW mode: enter the remote fiber loop-back command.
• Use a bit error test unit to run a bit error test.
• Verify the remote fiber connection by starting a local fiber loop-back:
- HW mode: set the local converter to fiber loop-back (see page 7).
- SW mode: enter the remote fiber loop-back command.
• Use a bit error test unit to run a bit error test.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
NO
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
FiberT1 T1
Local
Converter
Remote
Converter
Bit Error Test
Equipment
Remote
Device
FiberT1 T1
Local
Converter
Remote
Converter
Remote
Device
Bit Error Test
Equipment