6. Is Data Transfer Failing?
YES
• Verify the local copper connection by starting a local copper loop-back
(set the loop-back switch on the local Device to “CL”) and then use a bit error
test unit at the local location to run a bit error test.
• Verify the local fiber connection by starting a local fiber loop-back at the
remote location (set the loop-back switch on the remote Device to “FL”) and
then use a bit error test unit at the local location to run a bit error test.
• Verify the remote copper connection by starting a local copper loop-back
at the remote location (set the loop-back switch on the remote Device to
“CL”) and then use a bit error test unit at the remote location to run a bit
error test.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
NO
• Proceed to step 7.
11
Declaration of Conformity
Name of Mfg: Transition Networks
10900 Red Circle Drive, Minnetonka MN 55343 U.S.A.
Model: SCSCF30xx-10x Series Device
Part Number: SCSCF3011-100, SCSCF3013-100, SCSCF3014-100,
SCSCF3015-100, SCSCF3016-100, SCSCF3017-100,
SCSCF3018-100, SCSCF3019-100, SCSCF3029-100,
SCSCF3029-101, SCSCF3029-102, SCSCF3029-103,
SCSCF3039-100
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the SCSCF30xx-10x to which this declaration refers is in
conformity with the following standards.
EN 55022:1998 Class A; EN 55024:1998; FCC Part 15 Subpart B; CFR 21 subpart J
61000-3-2:1995+A14:2000; 61000-3-3:1995;
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive(s) and Standard(s).
February, 2009
Stephen Anderson, Vice-President of Engineering Date
7. Is the SDC (Signal Detect / Coax) LED illuminated yellow?
YES
• A failure of the remote unit connected to the coax interface has caused
an Alarm Indication Signal (AIS) on the coax interface. Correct the
remote unit failure.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
NO
• Proceed to step 8.
8. Is the SDF (Signal Detect / Fiber) LED illuminated yellow?
YES
• A broken coax link has caused an Alarm Indication Signal (AIS) on the
fiber interface. Correct the coax link failure.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
NO
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.